Surge Protection 40A DIN 170 270V

POEL0001

Sold by Natural SystemsMore information

Auto-resettable 40 Amp surge protection switch for rail installation DIN. Protect the electrical installation of your crop with this single-phase voltage suppressor. Regulates the voltage received by the ballasts blocking or grounding higher voltages generated by unexpected voltage spikes.

It is very important to always install a suitable surge breaker in the electrical distribution board of your crop, premises or home.

In the event of an overvoltage spike above 270V or below 170V, the circuit breaker Overvoltages will completely disconnect the installation, and after 1 minute it will reconnect if the voltage is already correct, if not, it will keep waiting.

You don't have to be present for the installation to get it working again. This prevents unwanted breakage of everything the electrical equipment connected to the installation.

A surge protector becomes essential to optimize the electrical installation of your grow room or housing, especially in those areas where there are significant fluctuations in the network. These areas usually have serious voltage disturbances, sporadic or permanent caused by:

  • Long length of wiring from the utility company in remote areas
  • Poor cabling quality
  • Overload of utility company wiring
  • Failure of one of the phases in the installation of the supplying company
  • Areas of frequent power outages.

This surge protector does not have any buttons, since it is 100% automatic for disconnection and Connection. It only has 2 led indicators:

  • Green: to confirm that it is receiving voltage at the input and will be on whenever it is connected and there is electrical voltage at the input.
  • Red: to indicate that there has been an anomaly and it is protecting the installation by disconnecting the output.

To size the correct power it is necessary to take into account the approximate maximum intensity of the teams:

  • 1000W 5.8 Amp luminaire
  • Electronic ballast 3 Amps
  • Magnetic Ballast 3.2 Amps
  • LED 1000W 4.6 Amps
  • LED 630W 3 Amps
  • LED 440W 2 Amps
  • LED 240W 1.1 Ampere

It is necessary to calculate the total intensity of the installation to be connected, if it is insufficient it is possible install one in different areas or one with larger capacity.